Long-Span Terminal Steel for Public Hall Roofs

Steel Structure Airport Buildings

A terminal-scale roof follows form, hanging loads and the master plan, not a rectangular portal frame.

Terminal halls more often use grids, tubular trusses or irregular roofs. A portal frame rarely meets both form and hanging loads. Read the plan and hanging points before choosing a system.

Send plan, section, hanging loads and the code. If operations limit the site, give the work window. Unpublished terminal area or programme is not added.

Long-Span Terminal Steel for Public Hall Roofs

Phase II of Jinan Yaoqiang Airport appears only as an official headline; unpublished lots are omitted. Send master-plan data with an inquiry.

Shop drawings and erection need their own plan; a plant programme should not be copied.

Tiankai Southeast fabricates marked members from approved drawings and supports erection by mark number. Sizes, loads and delivery follow the confirmed design file and contract; this page does not turn uncalculated tonnage, thickness or time into a promise.

  • Read plan and hanging loads first
  • Put operations limits on the window
  • Do not copy a plant programme

Specifications

Part Roof / truss
Input Architectural scheme
Output Details and fabrication
Erection By site plan

Related products

FAQ

  • Can you fabricate from our drawings?

    Yes. Send structural, shop or detailing drawings and we will cut, weld, drill and coat to those drawings. Member sizes, connections and joints can be adjusted per project. If you only have an architectural layout, we can discuss loads, span and use, then propose a steel scheme.

  • Do you support site erection?

    Our core work is shop fabrication and delivery. We can supply erection drawings, piece marks and remote technical support. If you need a supervisor or erection assistance, state the programme and site conditions in the inquiry; we will assess it per project.

  • Is fire protection included?

    Fire protection depends on local code and the required fire rating. Some projects need only corrosion coating; others need intumescent paint or boards. Please state the fire rating and code in the inquiry. Site fire-coating work is not included unless confirmed in writing.

  • Which design software and drawing formats do you accept?

    Design and detailing follow the drawing set agreed for each project. Please send plans, elevations, sections, plus load, span, bay spacing and cladding requirements. PDF or common CAD formats are acceptable. A sketch or dimension list is enough for a first scheme before shop drawings.

Send an inquiry